The concept of superheat

2021年10月19日

We illustrated the concept of superheat in last week's article by boiling water and superheating steam in a moonshine still. This week we will apply this concept to refrigerant in an air conditioning system.  The still has been replaced with an evaporator. 
Read Article >

Behavioral characteristics of various compressor types pt. 2

2021年10月5日

So now it is time to provide the correct answer along with information on why it is correct and also information on why the others are incorrect.
Read Article >

Behavioral characteristics of various compressor types

2021年9月21日

When faced with a challenging A/C system problem, knowing what type of compressor you are dealing with can help streamline the diagnosis process. 
Read Article >

mac特斯拉项目

2021年8月26日

MACS is working on a project, to collect A/C charge information for Tesla vehicles, 我们需要你的帮助!
Read Article >

Field study: Incorrectly installed condensers

2021年8月10日,

I have handled numerous tech calls involving older GM trucks with incorrectly installed condensers.  In preparation for this series of MACS blogs, I discovered a salvage truck with one of these condenser repairs.  This gave me the opportunity to duplicate the incorrect installation and look for pitfalls and solutions.
Read Article >

Top three tips on orifice tube behavior

2021年7月20日

In the last four MACS blog articles we covered a lot of detailed information about orifice tube system behavior. We examined a system with a full refrigerant charge verses a 25% undercharge. Now it is time to condense it all down into three important takeaways.
Read Article >

Low refrigerant charge and the search for real data part 4

2021年7月13日

When we examined the pressure readings and vent temperature readings last week, there was nothing showing up that indicated any charge issues (even operating with the 25% undercharge).
Read Article >

Low refrigerant charge and the search for real data part 3

2021年7月6日

To place as much heat load on the system as possible, we turned the heat in the shop up on high and got it as hot as possible before beginning the test. When the temperature peaked at 89°, we began the test. We tried to keep it constant, but all the heat being generated by the engine in the test vehicle caused it to inch upward by 2.5° before the second test was concluded.
Read Article >

Low refrigerant charge and the search for real data: part 2

2021年6月29日

The purpose of the test was to run an orifice tube system with a full refrigerant charge and then with a 25% undercharge and compare pressure readings and temperatures at strategic points in the system.
Read Article >

What’s the word on R-134a price & 供应?

2021年6月24日

The email questions are already coming in, and they go kind of how you’d expect: What’s going on with the price of R-134a? Is there going to be a shortage of R-134a 供应?